125 resultados para clinical trial

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study is to compare the healing of deep, non-contained intrabony defects (i.e., with a ?80% 1-wall component and a residual 2- to 3-wall component in the most apical part) treated with either an enamel matrix derivative (EMD) or guided tissue regeneration (GTR) after 12 months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-surgical peri-implantitis therapies appear to be ineffective. Limited data suggest that ER:YAG laser therapy improves clinical conditions. The present study aimed at comparing the treatment effects between air-abrasive (AM) and Er:YAG laser (LM) mono-therapy in cases with severe peri-implantitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Chlorhexidine (CHX) rinsing after periodontal surgery is common. We assessed the clinical and microbiological effects of two CHX concentrations following periodontal surgery. MATERIALS AND METHODS: In a randomized, controlled clinical trial, 45 subjects were assigned to 4 weeks rinsing with a 0.05 CHX/herbal extract combination (test) or a 0.1% CHX solution. Clinical and staining effects were studied. Subgingival bacteria were assessed using the DNA-DNA checkerboard. Statistics included parametric and non-parametric tests (p<0001 to declare significance at 80% power). RESULTS: At weeks 4 and 12, more staining was found in the control group (p<0.05 and p<0.001, respectively). A higher risk for staining was found in the control group (crude OR: 2.3:1, 95% CI: 1.3 to 4.4, p<0.01). The absolute staining reduction in the test group was 21.1% (9 5% CI: 9.4-32.8%). Probing pocket depth (PPD) decreases were significant (p<0.001) in both groups and similar (p=0.92). No rinse group differences in changes of bacterial counts for any species were found between baseline and week 12. CONCLUSIONS: The test CHX rinse resulted in less tooth staining. At the study endpoint, similar and high counts of periodontal pathogens were found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mesh fixation during laparoscopic ventral hernia repair can be performed using transfascial sutures or metal tacks. The aim of the present study is to compare mesh shrinkage and pain between two different techniques of mesh fixation in a prospective randomized trial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the soft and hard tissue healing and remodeling around tissue-level implants with different neck configurations after at least 1 year of functional loading. Material and methods: Eighteen patients with multiple missing teeth in the posterior area received two implants inserted in the same sextant. One test (T) implant with a 1.8 mm turned neck and one control (C) implant with a 2.8 mm turned neck were randomly assigned. All implants were placed transmucosally to the same sink depth of approximately 1.8 mm. Peri-apical radiographs were obtained using the paralleling technique and digitized. Two investigators blinded to the implant type-evaluated soft and hard tissue conditions at baseline, 6 months and 1 year after loading. Results: The mean crestal bone levels and soft tissue parameters were not significantly different between T and C implants at all time points. However, T implants displayed significantly less crestal bone loss than C implants after 1 year. Moreover, a frequency analysis revealed a higher percentage (50%) of T implants with crestal bone levels 1–2 mm below the implant shoulder compared with C implants (5.6%) 1 year after loading. Conclusion: Implants with a reduced height turned neck of 1.8 mm may, indeed, lower the crestal bone resorption and hence, may maintain higher crestal bone levels than do implants with a 2.8 mm turned neck, when sunk to the same depth. Moreover, several factors other than the vertical positioning of the moderately rough SLA surface may influence crestal bone levels after 1 year of function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Several studies have shown an association of cryptogenic stroke and embolism with patent foramen ovale (PFO), but the question how to prevent further events in such patients is unresolved. Options include antithrombotic treatment with warfarin or antiplatelet agents or surgical or endovascular closure of the PFO. The PC-Trial was set up to compare endovascular closure and best medical treatment for prevention of recurrent events. Methods The PC-Trial is a randomized clinical trial comparing the efficacy of percutaneous closure of the PFO using the Amplatzer PFO occluder with best medical treatment in patients with cryptogenic embolism, i.e. mostly cryptogenic stroke. Warfarin for 6 months followed by antiplatelet agents is recommended as medical treatment. Randomization is stratified according to patients age (<45 versus ≥45 years), presence of atrial septal aneurysm (ASA yes or no) and number of embolic events before randomization (one versus more than one event). Primary endpoints are death, nonfatal stroke and peripheral embolism. Discussion patients were randomized in 29 centers of Europe, Canada, and Australia. Randomization started February 2000. Enrollment of 414 patients was completed in February 2009. All patients will be followed-up longitudinally. Follow-up is maintained until the last enrolled patient is beyond 2.5 years of follow-up (expected in 2011).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proper sample size estimation is an important part of clinical trial methodology and closely related to the precision and power of the trial's results. Trials with sufficient sample sizes are scientifically and ethically justified and more credible compared with trials with insufficient sizes. Planning clinical trials with inadequate sample sizes might be considered as a waste of time and resources, as well as unethical, since patients might be enrolled in a study in which the expected results will not be trusted and are unlikely to have an impact on clinical practice. Because of the low emphasis of sample size calculation in clinical trials in orthodontics, it is the objective of this article to introduce the orthodontic clinician to the importance and the general principles of sample size calculations for randomized controlled trials to serve as guidance for study designs and as a tool for quality assessment when reviewing published clinical trials in our specialty. Examples of calculations are shown for 2-arm parallel trials applicable to orthodontics. The working examples are analyzed, and the implications of design or inherent complexities in each category are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The concept of platform switching has been introduced to implant dentistry based on observations of reduced peri-implant bone loss. However, randomized clinical trials are still lacking. This study aimed to test the hypothesis that platform switching has a positive impact on crestal bone-level changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The temporal pattern of bone-level alterations in conventionally restored implants is dependent upon healing mode (open or submerged). This study examined the influence of healing on marginal bone levels at implants with a medium-rough surface including the implant collar and a clearance-fit implant-abutment connection restored according to a platform-switching concept.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To analyze maintenance service of fixed maxillary prostheses and overdentures based on conventional gold bars or titanium bars and frameworks fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology.